VENTRICULAR ASSIST DEVICE
RECIPIENT - LEFT, RIGHT, or BIVENTRICULAR |
ALTERNATE NAMES
|
VAD; Left Ventricular Assist Device Recipient; LVAD Recipient; Right Ventricular Assist
Device Recipient; RVAD Recipient; Biventricular Assist Device Recipient; BiVAD Recipient;
Heart Pump Recipient; Implantable Ventricular Assist Device Recipient; Implantable
VAD Recipient; Long Term Ventricular Assist Device Recipient; Long Term VAD Recipient;
Left Ventricular Assist System Recipient; LVAS Recipient; Heart Assist System Implantation
Recipient
|
DESCRIPTION
|
A Ventricular Assist Device (VAD) is a mechanical pump surgically implanted to assist
the heart in pumping blood. The two basic types of VAD are the left ventricular assist
device (LVAD) and the right ventricular assist device (RVAD). If both the LVAD and
RVAD are used at the same time, then they are called a biventricular assist device
(BiVAD). VADs are implanted in people who have weakened hearts or advanced heart failure.
There are three primary reasons for implanting a VAD:
-
1.
VADs are used during or after surgery, until a weakened heart recovers (“bridge to
recovery”).
-
2.
VADs are used for people waiting for a heart transplant until a donor heart can be
obtained (“bridge to transplant”).
-
3.
VADs are used as a long-term treatment for people with end stage heart failure who
are not candidates for heart transplant (for example, people with clotting disorders,
irreversible kidney failure, severe liver disease, or infections that cannot be treated
with antibiotics). This is also known as “destination therapy.”
|
DIAGNOSTIC TESTING, PHYSICAL FINDINGS, AND
ICD-9-CM/ICD-10-CM
CODING
|
Diagnostic testing: The diagnostic indicators that are evaluated prior to a VAD placement may include:
-
-
-
-
•
Blood tests to monitor for infections.
Physical findings:
-
•
Coronary artery disease and heart attack;
-
-
-
•
Damage to the heart muscle (cardiomyopathy);
-
•
Myocarditis (inflammation of the heart muscles);
-
•
Congenital heart defects; and
-
•
Abnormal heart rhythms (heart arrhythmias).
ICD-9:
428.9
ICD-10: Z95.811
|
PROGRESSION
|
Prior to implantation of the VAD, individuals are admitted into the hospital to prepare
them for surgery. During this time, patients receive instruction on how the device
works, safety precautions, how to respond to alarms, what to do in the event of a
loss of electrical power, personal care before and after the implant, and how to prepare
for changes in activities of daily living. Following implantation, there is a risk
of infection, internal bleeding, heart failure, and mechanical breakdown of the VAD.
Response to implantation of a VAD depends on the severity of the heart condition.
Individuals with complications following surgery may require cardiac rehabilitation.
Cardiac rehabilitation involves prescribed exercise training, education on heart healthy
living, and counseling to reduce stress. VAD recipients are medically monitored on
a regular basis.
|
TREATMENT
|
People who require mechanical circulatory support of a VAD may require prolonged ventilation
due to postoperative respiratory failure. Mobility is often limited due to multiple
medical problems, life-support or monitoring equipment and weakness. These individuals
may require physical therapy intervention, respiratory therapy, and cardiac rehabilitation
on a case-by-case basis.
|
SUGGESTED PROGRAMMATIC ASSESSMENT*
|
Suggested MER for Evaluation:
-
•
Clinical description of findings;
-
•
Hospital admission and discharge summary;
-
-
-
-
-
|
Suggested Listings for
Evaluation: |
DETERMINATION |
LISTING
|
REMARKS |
Meets |
|
|
Equals |
4.09 |
Documentation of 90 consecutive days or more of implanted VAD establishes listing-level
medical equivalence of 4.09. Choose one-year diary from the date of surgical implantation
of VAD. After one year following the date of surgical implantation, evaluate residual
impairment(s).
|
104.09 |
Documentation of 90 consecutive days or more of implanted VAD establishes listing-level
medical equivalence of 104.09. Choose one-year diary from the date of surgical implantation
of VAD. After one year following the date of surgical implantation, evaluate residual
impairment(s).
|
* Adjudicators may, at their discretion, use the Medical Evidence of Record or the
listings suggested to evaluate the claim. However, the decision to allow or deny the
claim rests with the adjudicator.
|